Buscar

CcM1-DC

50,00 IVA no incluido

Single-phase direct current meter.

It is the most basic of our meters and measures the continuous current flowing through a phase. It is designed to be physically linked to the rest of the CcM devices and provides an economic solution to know secondary consumptions within a larger installation.

Description

What is the function of the CcM1-DC DC current meter?

The CcM1-DC is one of the devices of the CcM Smart metering family, which serves to measure direct current by means of a magnetic sensor, and deliver the data via a Modbus RTU connection using an RS-485 bus.

The Smart Meter CcM family of meters consists of a set of devices whose objectives are energy efficiency, reducing power consumption, submetering and/or monitoring of electrical parameters in switchboards of single-phase and three-phase installations, preferably housed in circuit breakers or differential switches. They are ideal for retrofit situations in existing switchboards.

¿Cómo funciona nuestro medidor de corriente continua CcM1-DC?

Specifically, the current meter continuous CCcM1-DC is part of the CcM family devices known as "secondary" as they only exist within the secondary bus, in which the "primary" devices of the CcM Smart metering (CcM4, and CcM2) act as masters by interrogating the CcM1-DC as slaves and feeding them.

Unlike the "main" devices of the CcM family, which are connected to the principal bus communications bus directly and are capable of measuring current, voltage, power, energy and harmonic distortion, the CcM1-DC DC meter hangs from the secondary bus of any of the main equipment and measures DC current.

How to connect the CcM1-DC DC current meter? 

In the case of CcM1-DC DC meters, it is recommended that they be connected via a communications and power cable (secondary bus) to a primary device of the CcM Smart meter (CcM4 and CcM2), and these in turn will acquire the data from their CcM1-DC slaves and make it available to the main bus, although there is the possibility to interrogate it directly through Modbus RTU commands, but this configuration forces to power the devices externally, since the power included in the four-wire cable that connects and configures the secondary communications bus between main and secondary devices of the CcM family is lost.

CcM1-DC Technical Specifications 
Maximum working intensity±50 A
Rango de medida de intensidad en DC[-30, +30] A
Intensity measurement error< 1 % F.S.
Communication protocolModbus RTU
Tiempo de respuesta medio0.1 s
Maximum consumption100 mW
Typical power supply12 VDC

Dimensions 
Total dimensions42 x 18 x 26 mm
Comb dimensions12 x 5 x 3 mm

Environmental conditions 
Working altitude0…2000 m
Working temperature-25...+50 °C
Overvoltage categoryIII (según IEC 61010-1 + IEC 61010-2-030)
Degree of protectionIP20
Degree of contamination2
Relative humidity0...95 % a 45 °C
Overcurrent protectionExternal device (switch or fuse holder base)